Sign In | Join Free | My himfr.com
Home > Automation Control Relays >

3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation

    Buy cheap 3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation from wholesalers
     
    Buy cheap 3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation from wholesalers
    • Buy cheap 3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation from wholesalers
    • Buy cheap 3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation from wholesalers
    • Buy cheap 3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation from wholesalers
    • Buy cheap 3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation from wholesalers

    3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation

    Ask Lasest Price
    Brand Name : SIEMENS
    Model Number : 3TF
    Certification : CE,CCC etc.
    Price : USD8~USD398(~3P/400A)
    Payment Terms : T/T, Western Union
    Supply Ability : 1,000pcs/month
    Delivery Time : 5-8 working days or bulk order negotiate
    • Product Details
    • Company Profile

    3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation

    SIEMENS 3TF IEC Contactor 9A,12A,16A,38A,45A,63A,85A,110A,205A up to 400A, AC-3 AC-1 Coil Voltage 24V,110V,230V,380V


    characteristic
    • Current range 09~400A;
    • AC, DC control coil is optional;
    • Different types of starters are available: standard motor start contactors, reversible contactors, star-delta starters, autotransformer starters, etc.
    • Product Certification: CCC, CE, CCS;


    Advantage
    • Compact installation
    > Surge suppressor installation requires no tools and can be inserted directly into the contactor without taking up more space
    > Reversible contactor is only 90mm wide, mechanical interlocking does not take up extra space, installation takes almost no time
    > Starter components provide pre-wired modules for quick and easy assembly
    • Highly integrated
    > to 100A contactor integration 1 normally open / 1 normally closed auxiliary contact
    > DC coil with built-in bidirectional suppression diode
    > Reversible contactor group with built-in bidirectional suppression diode
    •Safe and reliable
    > The main circuit and control circuit of the control and protection components are clearly distinguished
    > Mirrored contact design that meets safety standards, ensuring 10 million reliable actions
    > Protective cover prevents accidental contact of the contactor
    • outstanding quality
    > DC coils have a wide range of control voltages (0.7~1.25Uc)
    > Strong earthquake resistance
    > lower noise
    > Increased terminal strength

    > Permanent torque, reliable installation
    > Compact and space saving
    > Easy to install, saves time

    > Easy to maintain and save costs


    main information

    Product Series

    3TF

    product name

    AC Contactor

    product type

    Contactor

    Product short name

    3TF

    Contactor application area

    Applied to AC loads with a power factor greater than or equal to 0.95
    Squirrel cage motor for switching on and off normal start

    Use category

    AC-3
    AC-1
    AC-4

    Number of poles

    3P

    Power pole contact composition

    3 NO

    Rated working voltage [Ue]

    Power circuit: <= 690 V AC 25...400 Hz
    Power circuit: <= 300 V DC

    Rated operating current [Ie]

    18 A 60 °C) on <= 440 V AC AC-3 Applicable power circuit
    32 A 60 °C) on <= 440 V AC AC-1 for power supply circuit

    Motor power (kW)

    4 kW on 220...230 V AC 50/60 Hz (AC-3)
    7.5 kW on 380...400 V AC 50/60 Hz (AC-3)
    9 kW on 415...440 V AC 50/60 Hz (AC-3)
    10 kW on 500 V AC 50/60 Hz (AC-3)
    10 kW on 660...690 V AC 50/60 Hz (AC-3)
    4 kW on 400 V AC 50/60 Hz (AC-4)

    Motor power HP (UL / CSA)

    1 hp on 115 V AC 50/60 Hz for 1-phase motors
    3 hp on 230/240 V AC 50/60 Hz for 1-phase motors
    5 hp on 200/208 V AC 50/60 Hz for 3-phase motors
    5 hp on... 230/240 V AC 50/60 Hz for 3-phase motors
    10 hp on 460/480 V AC 50/60 Hz for 3-phase motors
    15 hp on 575/600 V AC 50/60 Hz for 3-phase motors

    Control loop characteristics

    AC on 50/60 Hz

    Control loop voltage

    230 V AC 50/60 Hz

    Auxiliary contact type

    1 NO + 1 NC

    Rated impulse withstand voltage [Uimp]

    6 kV in accordance with IEC 60947

    Overvoltage category

    III

    Conventional heating current [Ith]

    10 A on <60 °C for signal circuit
    32 A on <60 °C for power supply circuit

    Rated turn-on capability [Irms]

    140 A AC suitable signal circuit in accordance with IEC 60947-5-1
    250 A DC suitable signal loop in accordance with IEC 60947-5-1
    300 A on 440 V applicable power supply circuit in accordance with IEC 60947

    Rated breaking capacity

    300 A on 440 V applicable power supply circuit in accordance with IEC 60947

    Rated short-time withstand current [Icw]

    145 A on <40 °C - 10 s for power supply circuit
    240 A on <40 °C - 1 s for power supply circuit
    40 A on <40 °C - 10 minutes for power circuit
    84 A on <40 °C - 1 minute for power circuit
    100 A - 1 s for signal circuits
    120 A - 500 ms Applicable signal loop
    140 A - 100 ms for signal circuits

    Fuses used with relays

    10 A gG Applicable signal circuit in accordance with IEC 60947-5-1
    50 A gG on...<= 690 V with type 1 for power supply circuit
    35 A gG on ...<= 690 V with type 2 for power supply circuit

    Average impedance

    2.5 mΩ - Ith 32 A 50 Hz for power supply circuits

    Rated insulation voltage [Ui]

    Power circuit: 690 V in accordance with IEC 60947-4-1
    Power circuit: 600 V CSA certification
    Power circuit: 600 V UL certification
    Signal loop: 690 V in accordance with IEC 60947-1
    Signal loop: 600 V CSA certified
    Signal circuit: 600 V UL certification

    Electrical life

    1.65 kA2.s 18 A AC-3 Ue condition <= 440 V
    1 kA2.s 32 A AC-1 Ue condition <= 440 V

    Power consumption per pole

    2.5 W AC-1
    0.8 W AC-3

    Safety cover

    band

    Installation method

    Rail mounting
    Base plate installation

    standard

    CSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508


    Quality 3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation for sale