Sign In | Join Free | My himfr.com
Home > ATS Automatic Transfer Switch >

Dual Power Automatic Transfer Switch High Sensitive Response Circuit Breaker Changeover 220V (100/4P)

Wuxi Fenigal Science & Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Dual Power Automatic Transfer Switch High Sensitive Response Circuit Breaker Changeover 220V (100/4P) from wholesalers
     
    Buy cheap Dual Power Automatic Transfer Switch High Sensitive Response Circuit Breaker Changeover 220V (100/4P) from wholesalers
    • Buy cheap Dual Power Automatic Transfer Switch High Sensitive Response Circuit Breaker Changeover 220V (100/4P) from wholesalers
    • Buy cheap Dual Power Automatic Transfer Switch High Sensitive Response Circuit Breaker Changeover 220V (100/4P) from wholesalers
    • Buy cheap Dual Power Automatic Transfer Switch High Sensitive Response Circuit Breaker Changeover 220V (100/4P) from wholesalers

    Dual Power Automatic Transfer Switch High Sensitive Response Circuit Breaker Changeover 220V (100/4P)

    Ask Lasest Price
    Brand Name : Fenigal
    Model Number : Fenigal
    Certification : CE
    Payment Terms : T/T, Western Union
    Delivery Time : 5-8 working days
    • Product Details
    • Company Profile

    Dual Power Automatic Transfer Switch High Sensitive Response Circuit Breaker Changeover 220V (100/4P)


    image.png

    image.png

    • ✅【Superior Performance】Automatic transfer switch noiseless operation, energy saving, easy installation, simple operation and reliable performance.
      ✅【Features】The automatic transfer switch is reasonable structure, small size, beautiful appearance, equipped with protective cover, power supply is more safe and reliable.
      ✅【Fit for】This automatic transfer change-over switch especially suitable for office buildings requiring fire fighting. Please choose to buy according to actual needs.
      ✅【Safe to Use】Dual power automatic transfer switch have complete protection function, short circuit, overload, lack of phase, undervoltage protection. You can buy and use with confidence.
      ✅【EPS Fire Power Supply】The dual electronic power automatic circuit breaker adopted EPS fire power supply interface, DC12-24v can reliably long distance double point.

    About this item

    Silver contacts :The use of silver contacts can greatly improve the conductivity and service life of the product

    Easy to use :Built in regular standby opening output port, which can be connected with indicator light, which is convenient for observation outside the cabinet

    Good performance :Using high quality flame retardant plastic material, good insulation, high temperature proof, anti aging, safe and reliable

    Safety first :When the normal power supply is abnormal, the backup power supply will work immediately to ensure the continuity, reliability and safety of the power supply

    Suitable for :Suitable for switching to the backup power supply when the power is cut off, and switching to the main power supply when the power comes in


    Specification:

    Item Type:Dual Power Automatic Transfer Switch
    Model:FEQ5-100/4P
    Material:Plastic
    Product Dimensions ‏ : ‎

    0.39 x 0.39 x 0.39 inches; 1.57 Pounds


    Purpose:Switch to the backup power supply when the power fails, and switch to the main power supply when the power comes in
    Working Frequency:50-60HZ
    Rated Current:100A
    Rated Voltage:AC110-230V
    Working Voltage:AC220V
    Operation Mode:Automatic and manual
    ATS:CB level
    Conversion Time:≤0.05 (S)
    Number of Poles:4P
    Package List:1 x Dual Power Automatic Transfer Switch,1 x User Manual

    image.png

    How To Use:

    · 1. Place the automatic transfer switch of the dual power supply on the debugging platform, and connect the corresponding power line according to the correct phase sequence. The phase line and the neutral line are connected in position, and the wrong connection is not allowed.

    · 2. When debugging the three-pole switch, the common and spare neutral wires should be connected to the neutral terminal (NN and RN) respectively.

    · 3. Set the dual power supply automatic transfer switch to work in the self-turning and self-resetting mode. If the voltage of the two power supplies is normal, the switch should be placed in the common power supply position, and the common power supply is closed.

    · 4. Set the common power supply NA, NB, NC, NN for any phase loss, the dual power supply should be automatically converted to the backup power supply, if the common power supply returns to normal, it should be converted back to the common power supply

    Quality Dual Power Automatic Transfer Switch High Sensitive Response Circuit Breaker Changeover 220V (100/4P) for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wuxi Fenigal Science & Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)